Backflow FAQs

Backflow FAQs2020-10-05T11:18:27-04:00
What is back pressure?2017-07-03T23:12:25-04:00

Back pressure is the result of a higher pressure upstream than in its water supply. This can come from pumps or thermal expansion.

How long does a backflow test take?2017-07-01T21:18:56-04:00

Most tests can be performed in ten minutes. If there are any issues it could take a few more minutes.

Will my water be shut off for the backflow test?2017-07-01T21:17:56-04:00

Yes. All backflow devices require the water to be off for the test.

Do I have to be home for the backflow test?2017-07-01T21:16:14-04:00

If the valve is outside and accessible then no you do not need to be home.

Can I test my own backflow?2017-07-01T21:14:37-04:00

The anwser is no. A backflow test must be done by a certified tester. All municipalities only accept certified testers which requires schooling .  Testing a backflow also requires special equipment.

Why do I have to test my Backflow?2017-07-01T21:13:35-04:00

Florida law requires all municipalities to maintain a backflow program and this includes annual testing of all valves. Backflow testing insures these vales are protecting the water source.

What is a backflow device?2017-07-01T21:11:59-04:00

A backflow prevention device is a valve that lets water flow one way. Once the water flows thru the device it will no longer be able to flow back into the water source. Most backflow assemblies are located upstream of the water meter.

What is a backflow?2017-07-01T20:51:02-04:00

Backflow is a plumbing term for an unwanted flow of water in the reverse direction. It can be a serious health risk for the contamination of potable water source.

What is a DC or Double check valve assembly?2017-07-01T21:02:34-04:00

An assembly composed of two single, independently acting, check valves, including tightly closing shutoff valves located at each end of the assembly and suitable connections for testing the water tightness of each check valve. A check valve is a valve that is drip-tight in the normal direction of flow when the inlet pressure is one psi and the outlet pressure is zero. The check valve shall permit no leakage in a direction reverse to the normal flow. The closure element (e.g. clapper) shall be internally weighted or otherwise internally loaded to promote rapid and positive closure.

What is a PVB or Pressure vacuum breaker?2017-07-01T21:03:08-04:00

A pressure vacuum breaker is similar to an atmospheric vacuum breaker except that the checking unit “poppet valve” is activated by a spring. This type of vacuum breaker does not require a negative pressure to react and can be used on a pressure side of a valve.

What is a AVB or Atmospheric vacuum breaker?2017-07-01T21:04:06-04:00

A backflow prevention device which is operated by atmospheric pressure in combination with the force of gravity. The unit is designed to work on a vertical plane only. The one moving part consists of a poppet valve which must be carefully sized to slide in a guided chamber and effectively shut off the reverse flow water when a negative pressure exists.

What is a RP or Reduced pressure backflow preventer?2017-07-01T21:05:55-04:00

A device containing within its structure a minimum of two independently acting approved check valves, together with an automatically operating pressure differential relief valve located between the two check valves. The first check valve reduces the supply pressure a predetermined amount so that during normal flow and at cessation of normal flow the pressure between the checks shall be less than the supply pressure. In case of leakage of either check valve, the differential relief valve, by discharging to the atmosphere, shall operate to maintain the pressure between the checks less than the supply pressure. The unit shall include tightly closing shutoff valves located at each end of the device, and each device shall be fitted with properly located test cocks.

What is a Air Gap?2017-07-01T21:06:34-04:00

A physical separation between the free-flowing discharge end of a potable water supply pipeline and an open or non-pressure receiving vessel. An “approved airgap separation” shall be at least double the diameter of the supply pipe measured vertically above the top of the rim of the vessel. In no case shall it be less than 1 inch.